  Datasheet File OCR Text:
 Isolated, Linearized, Thermocouple Input 3B47
FEATURES
Interfaces, amplifies, filters, isolates, & linearizes analog input voltages from a J, K, T, E, R, S or B-type thermocouple Thermocouple input signal is internally linearized High accuracy internal cold junction compensation. Module provides +1500 V peak of galvanic transformerbased isolation with a common mode rejection (CMR) of 160 dB @ 50/60 Hz and a normal mode rejection (NMR) of 60 dB @ 50/60 Hz. All 3B47 series modules are mix-and-match and Hot Swappable.
FUNCTIONAL BLOCK DIAGRAM
Figure 1. 3B47 Functional Block Diagram
APPLICATIONS
Industrial signal conditioning Industrial signal isolation Industrial signal filtering
Output modules accept 0 to +10V (or +10V) single-ended signals and provide an isolated 4-20 mA (or 0-20 mA) process signal. All modules feature a universal pin-out and may be readily hot-swapped under full power and interchanged without disrupting field wiring. The Analog Devices 3B Series Signal Conditioning Subsystem is designed to easily handle signal conditioning problems in measurement and control applications. Some typical uses are in microcomputer-based data acquisition systems, programmable controllers, analog recorders, dedicated control systems, and any other applications where monitoring of temperature, pressure, flow and analog signals are required. Since each input module features two simultaneous outputs, the voltage output can be used to provide an input to a microprocessor-based data acquisition or control system while the current output can be used for analog transmission, operator interface, or an analog backup system. Each input module is a single-channel signal conditioner which plugs into a socket on the backplane and accepts its signal from the input screw terminals. All input modules provide input protection, amplification and filtering of the input signal, accuracy of +0.1%, low drift of +1 uV/ oC (low-level input modules), and feature two high-level analog outputs that are compatible with most process instrumentation. The isolated input modules also provide +1500 V peak isolation. The choice of a specific 3B module depends upon the type of input signal. Input modules are available to accept millivolt, volt, process current, thermocouple, RTD, AC and DC strain gage, frequency and LVDT inputs. The voltage output of each module is available from the system I/O connector while the current output is available on the output screw terminals.
PRODUCT OVERVIEW
The 3B Series of Signal Conditioning I/o Subsystems provide a low-cost, versatile method of transferring analog transducer signals to a data acquisition, monitoring or control system without the inherent noise, non-linearity, drift and extraneous voltages. The modules are designed to directly accept analog signals from Thermocouples, RTD's, AC and DC Strain Gages, Torque Transducers, Frequency Transducers, LVDTs, millivolt or process current signals. The modules amplify, isolate, linearize and convert the transducer output signals to standardized analog inputs for high-level analog I/O subsystems. The 3B Series Subsystem consists of a 10" relay rack with universal mounting backplane and a family of plug-in (up to 16 per rack) input and output signal conditioning modules. Eight and four channel backplanes are also available. Each backplane incorporates screw terminals for sensor inputs and current outputs and a 26-pin connector for high-level singleended voltage outputs to the user's equipment. The input modules feature complete signal conditioning circuitry optimized for specific sensors or analog signals and provide two simultaneous high-level analog outputs: 0 to +10V (or +10V) and 4-20 mA (or 0-20 mA).
Rev. 0
Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to change without notice. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and registered trademarks are the property of their respective companies.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. www.analog.com Tel: 781.329.4700 Fax: 781.326.8703 (c) 2004 Analog Devices, Inc. All rights reserved.
3B47 GENERAL DESCRIPTION
The 3B47 is a single-channel isolated thermocouple signalconditioning module which interfaces, amplifies, isolates, protects, linearizes and filters analog input voltages from a J, K, T, E, R, S or B-type thermocouple. The thermocouple input signal is internally linearized to provide an output voltage which is linear with temperature, High accuracy internal cold junction compensation and a predictable upscale open circuit indication provide a complete signal conditioning solution. To accurately measure low level signals in electrically noisy environments, +1500 V peak of galvanic transformer-based isolation with a common mode rejection (CMR) of 160 dB @ 50/60 Hz and a normal mode rejection (NMR) of 60 dB @ 50/60 Hz are provided. This plug-in, mix-and-match, hot-swappable module is easily field calibrated via front-panel zero and span adjustments. A chopper-stabilized low-drift input amplifier assures stable long-term stability. At the amplifier input, a zero-scale input voltage is subtracted from the input signal to set the zero-scale value. For user convenience, the zero and span optionally can be factory configured to meet custom needs (Model 3B37. CUSTOM). Zero suppression can exceed 100% of the input range. This enables suppression of a zero-scale input value many times larger than the total span for precise expandedscale measurements of a selection portion of an input signal. The differential input circuit on the field side is fully floating, eliminating the need for any input grounding. Signal isolation by transformer coupling uses a proprietary modulation technique for linear, stable and reliable performance. A demodulator on the computer side of the signal transformer recovers the original signal which is then filtered and buffered to provide a low-noise, low-impedance output voltage. Internal cold-junction compensation largely corrects errors arising from parasitic thermocouples formed by thermocouple connection to the input screw terminals, providing an accuracy of +0.5oC over the +5oC to +45oC ambient temperature range. The module generates a predictable upscale signal to indicate an open thermocouple; for a downscale response, connect a 47 M, 0.25 Watt resistor across screw terminals 2 and 4 on the 3B Series backplane.
.
Figure 2
Rev. 0 | Page 2 of 8
3B47
3B47 Models Available
Model 3B47-J-01 3B47-J-02 3B47-J-03 3B47-K-04 3B47-K-05 3B47-T-06 3B47-T-07 3B47-E-08 3B47-R-09 3B47-S-10 3B47-B-11 3B47-Custom
1
Input Type Type J Type J Type J Type K Type K Type T Type T Type E Type R Type S Type B Type J, K, T, E, R, S, or B
Input Range 0C to +760C (32F to +1400F) -100C to +300C (-148F to +572F) 0C to +500C (+32F to +932F) 0C to +1000C (+32F to +1832F) 0C to +500C (+32F to +932F) -100C to +400C (-148F to +752F) 0C to +200C (+32F to +392F) 0C to +1000C (+32F to +1832F) +500C to +1750C (+932F to +3182F) +500C to +1750C (+932F to +3182F) +500C to +1800C (+932F to +3272F) *
Output Range 0 V to +10 V 0 V to +10 V 0 V to +10 V 0 V to +10 V 0 V to +10 V 0 V to +10 V 0 V to +10 V 0 V to +10 V 0 V to +10 V 0 V to +10 V 0 V to +10 V *
Accuracy1 0.76C 0.4C 0.36C 1.0C 0.38C 1.1C 0.3C 1.5C 1.6C 1.5C 3.3C *
The CJC sensor accuracy (refer to specification table) should be added to the module accuracy when computing system accuracy. * Custom Input/Output ranges are available. Refer to configuration guide.
3B47 Specifications
(typical @ +25C and 15 V dc, and +24 V dc Power) Description Input Ranges Thermocouple Types Standard Ranges Custom Ranges J, K, T, E, R, S, B Refer to Model Table 5 mV to 500 mV Output Range1 Voltage (RL > 2 K) Accuracy2 Initial @ +25C See Model Table Stability vs. Temperature Voltage Output Zero Span Zero and Span Adjustment Range
3
Model 3B47
0 V to +10 V
0.02C/C 25 ppm of Reading/C 5% of Span
Cold Junction Compensation (CJC)4 Initial Accuracy @ +25C Accuracy vs. Temperature, +5C to +45C Input Bias Current Input Resistance 0.5 C 0.5C (0.0125C/C) +15 nA 15 M Noise Input, 0.1 Hz to 10 Hz Bandwidth 0.2 V rms
Rev. 0 | Page 3 of 8
3B47
Output, 100 kHz Bandwidth Bandwidth, -3 dB Output Rise Time, 10% to 90% Span Open Input Response Open Input Detection Time Common-Mode Voltage (CMV) Input-to-Output, Continuous Transient 1500 V peak, maximum ANSI/IEEE C37.90.1-1989 Common Mode Rejection (CMR) 1 k Source Imbalance, 50/60 Hz Normal Mode Rejection, 50/60 Hz Input Protection Continuous Transient Voltage Output Protection Current Output Protection 220 V rms maximum ANSI/IEEE C37.90.1-1989 Continuous Short to Ground 130 V rms, continuous Power Supply Voltages Rated Operation Current Sensitivity Mechanical Dimensions (11.5 V dc to 16.5 V dc) +16 mA, -14 mA 0.01% span/V 3.15" x 3.395" x 0.775" (80.0 mm x 86.2 mm x 19.7 mm) Environmental Temperature Range Rated Performance Storage Relative Humidity RFI Susceptibility
1 2 3
100 V rms 3 Hz 200 ms Upscale 10 seconds
160 dB 60 dB
-25C to +85C -55C to +85C 0 to 95% @ +60C non-condensing 0.5% Span error @ 400 MHz, 5 Watt, 3 ft
Current output is not available with model 3B47. Includes the combined effects of repeatability, hysteresis, and nonlinearity. A wide range of zero suppression and span adjustment is available to enable field calibration. 4 When used with the CJC temperature sensor provided on the 3B Series backplane. Specifications subject to change without notice.
Rev. 0 | Page 4 of 8
3B47 PIN CONFIGURATIONS AND FUNCTIONAL DESCRIPTIONS
Figure 3 3B47 Input Field Connections
Table 1. Pin Function Descriptions--
Pin No. 1 2 3 4 Description N/C + N/C
Figure 4 . Model 3B Series Module, with pin-out assignments.
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although this product features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance degradation or loss of functionality.
Rev. 0 | Page 5 of 8
3B47 OUTLINE DIMENSIONS
Figure 5. Outline Dimensions
Rev. 0 | Page 6 of 8
3B47 NOTES
Rev. 0 | Page 7 of 8
3B47 NOTES
(c) 2004 Analog Devices, Inc. All rights reserved. Trademarks and registered trademarks are the property of their respective companies. D05162-0-9/04(0)
Rev. 0 | Page 8 of 8